Technical Specifications:
TECHNOLOGY
Line-interactive
FORMAT
Convertible tower/rack (2U)
INPUT
Rated voltage
208 / 220 / 230 / 240 V
Voltage range 100% load
170 ÷ 280 V
Stabiliser
AVR (Buck & Boost)
Rated frequency
50 / 60 Hz (auto-detection)
Frequency range
±5 Hz
Auto~detection of frequency
Yes
Protection
Fuse (800/1100) or resettable thermal cutoff (1500/2000/3000)
OUTPUT
Power factor
0.9
Rated voltage
208 / 220 / 230 / 240 V
Voltage accuracy (battery mode)
±1.5%
Power (VA/W)
2000 / 1800
Total harmonic distortion (THDv)
< 2% linear load / < 5% non-linear load
Waveform (battery mode)
Pure sine wave
Frequency
50/60 Hz (same as input)
Frequency accuracy (battery mode)
±0.1Hz
Admissible overloads in battery mode
< 120% off at 1 min / < 150% off at 10 s
Admissible overloads in-line mode
< 120% off at 5 min / < 150% off at 10 s / >150 %: 1 s
Socket type
IEC
No. Of sockets
8
Programmable sockets
Yes, for critical / non-critical loads (4/4)
BATTERY
Battery type
Pb-Ca sealed, AGM, maintenance-free
Charge type
I/U (constant current/constant voltage)
Recharge time
4 hours to 90%
Battery test
Automatic on every start + one x week
CHARGER
Temperature voltage compensation
Yes
COMMUNICATION
Ports
RS-232/USB-HID
Intelligent slot
Slot for SNMP/potential-free contacts/ MODBUS
Monitoring software
For Windows, Linux and Mac
INDICATIONS
Type
LCD + keypad
Values
Voltage, power and input and output frequency / Battery voltage / % battery charge / % load / Operating mode / Fault / Discharge time / Mute
Operating modes
Normal / Stabilisation (AVR) / Battery / Fault
Alarm
Output battery mode, polarity, low battery (back up time), charger failure and overload
Audible
Every 10 s for battery operation. Every 2 s for low battery / Polarity. Every 1 s for overcharge. Continuous for fault.
Failure
Display LCD
OTHER FUNCTIONS
Cold start (start-up from batteries)
Yes
Emergency stop (EPO)
Yes
ADSL/fax/modem transient protector
Yes
Green-function
Yes, automatic stop in battery mode with load <5%
Smart fan speed
Yes, smart control of fan speed
Site wiring fault
Yes, error detection of phase-neutral rotation and/or absence of earth
GENERAL
Operating temperature
0º C ÷ 40º C
Relative humidity
Up to 95%, non-condensing
Maxium operating altitude
2,400 masl (power degradation up to 5,000 m)
Acoustic noise at 1 metre
< 45dB
STANDARDS
Safety
EN IEC 62040-1
Electromagnetic compatibility (EMC)
EN IEC 62040-2 (C2)
Operation
EN IEC 62040-3
Corporate cerification
ISO 9001, ISO 14001, ISO 45001
DIMENSIONS
Depth (mm)
510
Width (mm)
438
Height (mm)
88
WEIGHT
Weight (kg)
21.5
V